A Comparative Study between Newtonian and Non-Newtonian Models in a Stenosis of a Carotid Artery

dc.contributorKumbhakonam, Rajagopal
dc.contributorRanjan, Devesh
dc.creatorKhambhampati, Tejasvi Krishna
dc.date.accessioned2015-12-01T06:31:10Z
dc.date.accessioned2017-04-07T20:07:59Z
dc.date.available2015-12-01T06:31:10Z
dc.date.available2017-04-07T20:07:59Z
dc.date.created2013-12
dc.date.issued2013-12-10
dc.description.abstractBlood, the most significant biological fluids plays a very vital role in the human mechanism, in terms of supplying the required nutrients to different parts of the human body, removing waste products and defending the body against infection through the action of antibodies. Therefore, it is imperative that blood flow must be studied in great detail. Hemodynamic analysis of blood flow in vascular beds and prosthetic devices requires the rheological behavior of blood to be characterized through appropriate constitutive equations relating the stress to deformation and rate of deformation. Numerical simulations, although not very accurate, provide an excellent alternative around this difficulty. As part of the preliminary studies, the Newtonian model of blood was assumed, and wall shear stresses have been plotted at certain critical points. Profiles of wall shear stress were then compared with the experimental results of Ku and Giddens. A numerical investigation of blood flow in stenosed carotid artery of the human body is presented in this thesis. Using a three-dimensional computational model of the stenosis, simulations were performed to capture the Non-Newtonian behavior of blood. The flow is considered as being pulsatile, with appropriate realistic boundary conditions. A shear thinning model (Carreau?s) and a visco-elastic model (Yeleswarapu?s Olydroyd-B model) have been employed to predict wall shear stress for the case of a healthy carotid artery and two cases of stenosed carotid artery models (50% and 90% stenosed carotid artery). From these simulation results, it was observed that wall shear stresses predicted by the models at certain critical points are different. Recirculation zones, flow separation and associated negative wall shear stress were observed in certain cases.
dc.identifier.urihttp://hdl.handle.net/1969.1/151909
dc.language.isoen
dc.subjectNon-Newtonian
dc.subjectpulsatile
dc.subjectblood flow
dc.subjectsimulations
dc.subjectstenoses
dc.subjectcarotid artery bifurcation
dc.subjectshear thinning models
dc.subjectviscoelastic models
dc.titleA Comparative Study between Newtonian and Non-Newtonian Models in a Stenosis of a Carotid Artery
dc.typeThesis

Files