Home
    • Login
    View Item 
    •   TDL DSpace Home
    • Federated Electronic Theses and Dissertations
    • Texas A&M University at College Station
    • View Item
    •   TDL DSpace Home
    • Federated Electronic Theses and Dissertations
    • Texas A&M University at College Station
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Fabrication and Characterization of Poly(2-Hydroxyethyl Methacrylate) Microparticle Sensors

    Thumbnail
    Date
    2013-04-24
    Author
    Philip, Merene
    Metadata
    Show full item record
    Abstract
    Optical biosensors are desired for the monitoring of various biochemical markers, which are relevant indicators in the treatment and diagnosis of diseases. Specifically, luminescence sensors are favorable for optical interrogation since they are highly sensitive to analyte changes and may be implemented in lifetime or intensity-based systems. In order to develop particle-based fluorescent sensors, poly(2-hydroxyethylmethacrylate) (HEMA) microspheres have been fabricated via membrane emulsification and characterized to evaluate the emulsion method and the overall process of tailoring properties to synthesize spheres of specific mean sizes. A pH-sensitive indicator seminaphthorhodafluors-4F 5-(and-6)-carboxylic acid (SNARF) was immobilized within the microspheres, and resulting sensor particles were exposed to various pH buffers to obtain a pH calibration curve based on intensity measurements. PolyHEMA microparticles were fabricated in a systematic study with measured mean sizes ranging from 8-21 um. Optical and scanning electron microscopy images revealed the formation of spherical, porous particles, which were additionally stabilized with polymer coatings. The lowest coefficient of variation value achieved was 50%, indicating the inability to produce monodisperse particles due to the dispersity of pore sizes in the membrane. SNARF was immobilized within the polyHEMA spheres, and fluorescence was observed when exposing the sensors to different pH buffers on a fluorescence microscope. Ratiometric intensity measurements for the sensor particles were obtained on a spectrofluorometer while flowing pH buffers over the immobilized spheres in a reaction chamber. The peak intensity ratio of the microparticle sensors exhibited a change in 0.9 units when decreasing the pH from 8.4 to 5.5. In the future, these pH sensing particles may be implanted alongside glucose sensing materials in order to provide valuable pH information in understanding the immune response to specific biomaterials and sensing components.
    URI
    http://hdl.handle.net/1969.1/149293
    Collections
    • Texas A&M University at College Station

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by @mire NV