Browsing by Subject "inspection"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Inspection of Historic Steel Bridges Using Ultrasonic Phased Array(2014-01-16) Roldan Arcos, Alejandra LThe use of ultrasonic phased array (UPA) technology for inspection of the trunnion bearing pin of the 100-year old Salmon Bay Bascule Bridge is the focus of this research. To thoroughly investigate the bearing pin, two main objectives are addressed: the development of a UPA system, including the design of a case that uses a Poly Methyl Meth Acrylate (PMMA) material to house the transducer, and the implementation of the system in the field to test the feasibility of the UPA system and its application as a nondestructive testing unit. Two different testing settings are carried out in this research. The first study is performed in a lab-based setting on a mock-up model pin. This model is used as a reference to provide the calibration of the UPA system using the exterior edge, two keyholes, and three diagonal interior grease holes. The second study is performed in a field-based setting on the authentic trunnion bearing pin taken out of service from the Salmon Bay Bridge in Seattle, Washington, currently residing at the Riverside Campus. This pin has three similar diagonal holes, keyholes, and unknown internal defects. Realtime measurements using the UPA system is used to identify the exterior surfaces and the keyholes of the original pin. The results of the inspection of the pins using the UPA system indicate the accuracy of the real-time data taken from the probe measurements. It was limited to seeing perpendicular defects and exterior sides, and could not identify the diagonal grease hole within both pin parts. It did, however, identify the keyholes, and was later verified by visual inspection once the sleeves were removed. The original pin showed no internal defects. For future research in nondestructive testing used in historic trunnion pins, it is recommended to combine this technology with an automatic system that allows the reduction of human interaction with the inspection. A membrane-like surface adaptable to rough faces, along with a constant flow of water between the wedge and surface, would facilitate the need to remove the PMMA case out of the pin to re-apply couplant for inspections. Finally, a modified angled wedge could also be applied within the PMMA case to search for different angled cracking.Item Inspection, Assessment, and Repair of Grouted Ducts in Post-tensioned Bridge(2011-02-22) Im, Seok BeenSegmental post-tensioned (PT) bridges are major structures that carry significant traffic. Recent investigations of these bridges have identified voids in their ducts. and some of these exposed strands at these void locations are undergoing corrosion. The corrosion of strands may lead to the failure of tendons. As such, an effective inspection process for identifying these voids is needed. From a literature review, several non-destructive testing (NDT) methods are compared for applicability in inspecting voids in external tendons. The impact echo (IE), ultrasonic pulse velocity (UPV), and sounding inspection methods were selected and assessed for identifying voids in preliminary test setup. The sounding inspection method is further assessed for its effectiveness in identifying voids in a full-scale, external tendon system. The results indicate that the sounding inspection slightly underestimates the size of the voids. However, the inspected size and locations of voids have a close correlation with actual voids in ducts. Thus, the sounding inspection can be an effective tool for identifying voids because of its easy application in the field. Recently, the investigated failures of segmental post-tensioned (PT) bridges called attention to the rehabilitation and mitigation methods of voided ducts in PT structures. Although controversy exists on how to best protect PT tendons from corrosion, filling these voids with grout may be one option. An optimized grouting procedure for repairing these voids is needed how best to protect the strands from corrosive environments. This research investigates three grouting methods for efficiently repairing the voids in PT duct systems. These methods are (1) vacuum grouting (VG), (2) pressure grouting (PG), and (3) pressure-vacuum grouting (PVG). Each method is being evaluated for filling capability, filling performance, and economic feasibility. Also, three different pre-packaged grouts for repair are assessed in this research to propose the most suitable material for repairing voided PT ducts. The results indicate that the PG and PVG methods are more constructible and likely more economical than the VG method. However, the PVG and VG methods seem to be more effective than the PG method in filling the voids. As a result of these tests, the PVG method is recommended for filling voids in tendons. The results also show that C-1 and C-2 grouts have better filling capability than C-3 grout. Although experimental tests using prototype specimens of external PT tendons are performed to propose an effective repair grouting method and material, the experimental conditions cannot cover all voids types, duct types, and other effects of repair grouting methods in the field. Thus, the grout flow in voided ducts is predicted using a commercial Computational Fluid Dynamics (CFD) program. The simulation of the flow is challenging due to the complicated geometry of voided ducts, but the simplified model in this research shows close correlations with experimental results. Thus, various parameters of repair methods and materials are assessed in this research, and the PVG method with grouts having low viscosity exhibited the best performance. If it is determined that filling voids with grout is appropriate and prevents future corrosion, it is recommended that voids in the field be filled using the PVG method with grouts exhibiting low viscosities.