Browsing by Subject "Point-of-care"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Integrated impedance spectroscopy biosensors(2012-05) Manickam, Arun; Hassibi, Arjang; Neikirk, Dean P.; Pan, David Z.; Kavusi, SamAffinity-based biosensors, or in short biosensors, are extremely powerful and versatile analytical tools which are used for the detection of a wide variety of bio-molecules. In recent times, there has been a need for developing low-cost and portable affinity-based biosensor platforms. Such systems need to have a high density of detection sites (i.e biosensing elements) in order to simultaneously detect multiple analytes in a single sample. This has led to the creation of integrated biosensors, which make use of integrated circuits (ICs) for bio-molecular detection. In such systems, it has been demonstrated that by taking advantage of the capabilities of semiconductor and very large scale integrated (VLSI) circuit fabrication processes, it is possible to build compact miniaturized biosensors, which can be used in wide variety of applications such as in molecular diagnostics and for environmental monitoring. Among the various detection modalities for biosensors, Electrochemical Impedance Spectroscopy (EIS) permits real-time detection and has label-free detection capabilities. EIS is fully electronic in nature. Hence, it can be implemented using standard IC technologies. The versatility and ease of integration of EIS makes it a promising candidate for developing integrated biosensor platforms. In this thesis, we first examine the underlying principles of EIS method of biosensing. By analyzing an immunosensor assay as an example, we show that EIS based biosensing is a highly sensitive detection method, which can be used for the detection of a wide variety of analytes. Since EIS relies on small impedance changes in order to perform detection, it requires highly accurate models for the electrode-electrolyte systems. Hence, we also introduce a compact modeling technique for the distributed electrode-electrolyte systems with non-uniform electric fields, which is capable of modelling noise and other non-idealities in EIS. In the second part of this thesis, we describe the design and implementation of an integrated EIS biosensor array, built using a standard complementary metal-oxide-semiconductor (CMOS) process. The chip is capable of measuring admittance values as small as 10nS and has a wide dynamic range (90dB) over a wide range of frequencies (10Hz-50MHz). We also report the results obtained from the DNA and protein detection experiments performed using this chip.Item Microfluidics for bioanalytical research : transitioning into point-of-care diagnostics(2014-12) Scida, Karen; Crooks, Richard M. (Richard McConnell)In this dissertation, three different microfluidic devices with bioanalytical applications are presented. From chapter to chapter, the bioanalytical focus will gradually become the development of a point-of-care sensor platform able to yield a reliable and quantitative response in the presence of the desired target. The first device consists of photolithographically-patterned gold on glass bipolar electrodes and PDMS Y-shaped microchannels for the controlled enrichment, separation from a mixture, and delivery of two charged dyes into separate receiving microchannels. The principle for the permanent separation of these dyes is based on the concept of bipolar electrochemistry and depended on the balancing/unbalancing of convective and electromigrating forces caused by the application of a potential bias, as well as the activation/deactivation of the bipolar electrodes. Two different bipolar electrode configurations are described and fluorescence is used to optimize their efficiency, speed, and cleanliness of delivery. The second device is a DNA sensor fabricated on paper by wax printing and folding to form 3D channels. DNA is detected by strand-displacement induced fluorescence of a single-stranded DNA. A multiplexed version of this sensor is also shown where the experiment results in “OR” and “AND” Boolean logic gate operations. In addition, the nonspecific adsorption of the reagents to cellulose is studied, demonstrating that significant reduction of nonspecific adsorption and increased sensitivity can be achieved by pre-treating the substrate with bovine serum albumin and by preparing all analyte solutions with spectator DNA. The third device, also made of paper, has a novel design and uses a versatile electrochemical detection method for the indirect detection of analytes via the direct detection of AgNP labels. A proof-of-concept experiment is shown where streptavidin-coated magnetic microbeads and biotin-coated AgNPs are used to form a composite model analyte. The paper device, called oSlip, and electrochemical method used are easily coupled so the resulting sensor has a simple user-device interface. LODs of 767 fM are achieved while retaining high reproducibility and efficiency. The fourth device is the updated version of the oSlip. In this case, the objective is to show the current progress and limitations in the detection of real analytes using the oSlip device. A sandwich-type immunoassay approach is used to detect human chorionic gonadotrophin (pregnancy hormone) present in human urine. Various optimization steps are performed to obtain the ideal reagent concentrations and incubation time necessary to form the immunocomposite in one step, that is, by mixing all reagents at the same time in the oSlip. Additionally, improvements to the electrochemical detection step are demonstrated.Item Next generation transduction pathways for nano-bio-chip array platforms(2009-05) Jokerst, Jesse Vincent; McDevitt, John ThomasIn the following work, nanoparticle quantum dot (QD) fluorophores have been exploited to measure biologically relevant analytes via a miniaturized sensor ensemble to provide key diagnostic and prognostic information in a rapid, yet sensitive manner—data essential for effective treatment of many diseases including HIV/AIDS and cancer. At the heart of this “nano-bio-chip” (NBC) sensor is a modular chemical/cellular processing unit consisting of either a polycarbonate membrane filter for cell-based assays, or an agarose bead array for detection of biomarkers in serum or saliva. Two applications of the NBC sensor system are described herein, both exhibiting excellent correlation to reference methods ((R² above 0.94), with analysis times under 30 minutes and sample volumes below 50 [mu]L. First, the NBC sensor was employed for the sequestration and enumeration of T lymphocytes, cells specifically targeted by HIV, from whole blood samples. Several different conjugation methods linking QDs to recognition biomolecules were extensively characterized by biological and optical methods, with a thiol-linked secondary antibody labeling scheme yielding intense, specific signal. Using this technique, the photostability of QDs was exploited, as was the ability to simultaneously visualize different color QDs via a single light pathway, effectively reducing optical requirements by half. Further, T-cell counts were observed well below the 200/[mu]L discriminator between HIV and AIDS and across the common testing region, demonstrating the first reported example of cell counting via QDs in an enclosed, disposable device. Next, multiplexed bead-based detection of cancer protein biomarkers CEA, Her-2/Neu, and CA125 in serum and saliva was examined using a sandwich immunoassay with detecting antibodies covalently bound to QDs. This nano-based signal was amplified 30 times versus molecular fluorophores and cross talk in multiplexed experiments was less than 5%. In addition, molecular-level tuning of recognition elements (size, concentration) and agarose porosity resulted in NBC limits of detection two orders of magnitude lower than ELISA, values competitive with the most sensitive methods yet reported (0.021 ng/mL CEA). Taken together, these efforts serve to establish the valuable role of QDs in miniaturized diagnostic devices with potential for delivering biomedical information rapidly, reliably, and robustly.