Browsing by Subject "Building Energy"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Effect of Daylighting on Energy Consumption and Daylight Quality in an Existing Elementary School(Texas A&M University, 2005-08-29) Atre, Umesh VinayakThis research investigates the effects of daylighting in an existing elementary school in College Station, Texas. The conclusions are generalizable to similar school designs in hot and humid climates. This study focuses on the trends observed in the building??s heating, cooling, and lighting energy consumption due to daylighting, and the overall effect on total energy consumption. Skylights with 1% to 10% glazing surface to floor area and clerestories from 2 ft to 8 ft glazing height were analyzed to formulate balanced daylighting designs that could provide for decreased electricity and gas energy consumption and increased daylight illuminance levels and energy cost savings. Classroom and Library areas inside the case study school building were analyzed using walk-throughs and daylight factor measurements to understand existing lighting conditions and the potential for daylighting. Physical scale models of the study spaces with and without daylighting alternatives were built for daylight factor and daylight penetration analysis. Computer simulation models were created for the base case and all proposed daylighting designs for building energy performance evaluation using the DOE-2 building energy simulation program. Daylight factors from the actual spaces, physical model measurements, and computer simulation outputs were studied for trendsin interior daylight illuminance levels. Annual energy consumption analyses were performed using DOE-2 and involved heating, cooling, and electrical energy use comparisons of all proposed designs with the base case. One design each from the skylight and clerestory cases, and an overall design based upon the performance criteria are proposed for the existing school building. The building energy analyses suggested that a considerable reduction in artificial lighting and total electricity use could be achieved through proper sizing of skylights and clerestories. Heating energy use stayed almost constant in all cases. Considering all different trends in energy use, all the proposed cases perform better than the base case in terms of total energy savings. The spaces analyzed constituted 15% of total school area, and projected savings would be much higher if daylighting could be applied to the entire school building.Item Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis(2010-07-14) Kimla, JohnThe potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific system features. As the commissioning process has begun to require the prediction of savings, knowledge of the extent to which various SPR control strategies impact fan energy has become increasingly important. This research aims to document existing SPR control strategies and utilize building data and simulation to estimate fan energy use. A comprehensive review of the literature pertaining to SPR control was performed and the results were organized into a top-down flow chart tool. Based on the type of feedback available from a particular system, or lack thereof, this tool will facilitate the selection of a SPR control strategy. A field experiment was conducted on a single duct variable air volume system with fixed discharge air temperature and static pressure setpoints. Finally, an air-side model of the experimental system was created using detailed building design information and calibrated using field measurements. This model was used to estimate the fan energy required to supply the trended airflow data using fixed static pressure (FSP) and SPR control based on zone demand, system demand, and outside air temperature. While utilizing trend data from November 1, 2008 to February 12, 2009, the FSP control of the experimental system was used as the baseline for ranking the energy savings potential of nine different forms of duct static pressure control. The highest savings (73-74%) were achieved using zonal demand based SPR control. System demand based SPR control yielded savings ranging from 59 to 76%, which increased when the duct sensor was positioned near the fan discharge and under similar zone load conditions. The outside air temperature based SPR control yielded savings of 65% since the experimental system supplied primarily perimeter zones. Finally, increasing the FSP setpoint from 2 to 3 inWG increased fan energy by 45%, while decreasing the setpoint from 2 to 1 inWG decreased fan energy by 41%.