    14 MeV neutron generator dose modeling

    Thumbnail
    Date
    2013-12
    Author
    McConnell, Kristen Alycia
    Metadata
    Show full item record
    Abstract
    Modeling and understanding the doses around the neutron generator provides insightful data in regard to radiation safety and protection precautions. Published data can be used to predict doses, but realistic data for the Nuclear Engineering Teaching Laboratory’s Thermo MP 320 Neutron Generator helps health physicists more accurately predict dose rates and protect experimenters against exposure. The goal was to create a model inclusive of the entire setup and room where the neutron generator is housed. Monte Carlo N-Particle (MCNP) Code reigns as the preferred method for modeling radiation transport and was utilized to model the transport of neutrons within the current configuration of the 14 MeV neutron generator facility. This model took into account all shielding materials and their respective dimensions and locations within the concrete room. By utilizing tallies and tally modifiers, the model predicts dose rates that can be used with experimental factors such as irradiation time and flux to predict a dose in millirem. Validation experiments were performed in the current setup using Landauer Luxel®+ with Neutrak dosimeters placed in strategic locations to record the neutron dose vi received as well as a Ludlum Model 42-41 PRESCILA neutron probe to predict dose rates. The dosimeters and PRESCILA measurement locations matched the positions of the point detector tallies in MCNP. After laboratory analysis, a comparison was performed between the model output and the dosimeter and PRESCILA values to successfully validate the accuracy of the model.
    URI
    http://hdl.handle.net/2152/23577
    Collections
    • University of Texas at Austin

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by @mire NV