Sustainable Carbon Sequestration: Increasing CO2-Storage Efficiency through a CO2-Brine Displacement Approach

Date

2012-10-19

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

CO2 sequestration is one of the proposed methods for reducing anthropogenic CO2 emissions to the atmosphere and therefore mitigating global climate change. Few studies on storing CO2 in an aquifer have been conducted on a regional scale. This study offers a conceptual approach to increasing the storage efficiency of CO2 injection in saline formations and investigates what an actual CO2 storage project might entail using field data for the Woodbine aquifer in East Texas. The study considers three aquifer management strategies for injecting CO2 emissions from nearby coal-fired power plants into the Woodbine aquifer. The aquifer management strategies studied are bulk CO2 injection, and two CO2-brine displacement strategies. A conceptual model performed with homogeneous and average reservoir properties reveals that bulk injection of CO2 pressurizes the aquifer, has a storage efficiency of 0.46% and can only last for 20 years without risk of fracturing the CO2 injection wells. The CO2-brine displacement strategy can continue injecting CO2 for as many as 240 years until CO2 begins to break through in the production wells. This offers 12 times greater CO2 storage efficiency than the bulk injection strategy. A full field simulation with a geological model based on existing aquifer data validates the storage capacity claims made by the conceptual model. A key feature in the geological model is the Mexia-Talco fault system that serves as a likely boundary between the saline aquifer region suitable for CO2 storage and an updip fresh water region. Simulation results show that CO2 does not leak into the fresh water region of the iv aquifer after 1000 years of monitoring if the faults have zero transmissibility, but a negligible volume of brine eventually gets through the mostly sealing fault system as pressure across the faults slowly equilibrates during the monitoring period. However, for fault transmissibilities of 0.1 and 1, both brine and CO2 leak into the fresh water aquifer in increasing amounts for both bulk injection and CO2-brine displacement strategies. In addition, brine production wells draw some fresh water into the saline aquifer if the Mexia-Talco fault system is not sealing. A CO2 storage project in the Woodbine aquifer would impact as many as 15 counties with high-pressure CO2 pipelines stretching as long as 875 km from the CO2 source to the injection site. The required percentage of power plant energy capacity was 7.43% for bulk injection, 7.9% for the external brine disposal case, and 10.2% for the internal saturated brine injection case. The estimated total cost was $0.00132?$0.00146/kWh for the bulk injection, $0.00191?$0.00211/kWh for the external brine disposal case, and $0.0019?$0.00209/kWh for the internal saturated brine injection case.

Description

Citation