Home
    • Login
    View Item 
    •   TDL DSpace Home
    • Federated Electronic Theses and Dissertations
    • Texas A&M University at College Station
    • View Item
    •   TDL DSpace Home
    • Federated Electronic Theses and Dissertations
    • Texas A&M University at College Station
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Novel devices for analytical-scale isoelectric trapping separations

    Thumbnail
    Date
    2009-05-15
    Author
    Lim, Peniel Jason
    Metadata
    Show full item record
    Abstract
    Isoelectric trapping (IET), has proven to be one of the most successful electrophoretic techniques used for separations of ampholytic compounds. IET is carried out in multicompartment electrolyzers (MCEs) in which adjacent compartments are joined through buffering membranes whose pH values bracket the pI of the ampholytic component to be trapped in the compartment. The present small-scale instruments use plastics as their structural materials, which causes poor Joule heat dissipation. The separation compartments have cylindrical or pear-shaped interiors with large internal diameters, which create long heat transfer paths. The long electrode distances yield low field strengths that lead to low electrophoretic velocities for the analytes. These factors interrelatedly limit the electric power that can be applied to the system, contributing to long separation times. Furthermore, these devices do not offer a realistic solution to the problems associated with the detection of low abundance proteins. To address these problems, two novel IET devices have been developed for small-scale IET separations. The first device, named MSWIFT, was constructed using thermally conductive, high-purity alumina as the structural material of the separation compartments. By creating narrow, 0.1- or 0.2-mL channels in thin alumina blocks, the heat transfer path from the center of the compartment to the wall was significantly decreased; and the distance between electrodes was greatly shortened. MSWIFT achieved 6 to 50 times faster IET separations compared to other MCEs. The second device, named ConFrac, was developed to simultaneously fractionate and concentrate ampholytic components from a complex sample into 0.1-mL collection compartments. By designing a system with a 2-dimensional pH gradient and allowing recirculation of the sample feed, the ConFrac demonstrated enrichment of analytes by a factor of 100 and greater.
    URI
    http://hdl.handle.net/1969.1/ETD-TAMU-1652
    Collections
    • Texas A&M University at College Station

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    TDL
    Theme by @mire NV