Abstract

Texas Department of Transportation (TxDOT) is currently designing its highway bridge structures using the AASHTO Standard Specifications for Highway Bridges, and it is expected that TxDOT will make transition to the use of the AASHTO LRFD Bridge Design Specifications before 2007. The objectives of this portion of the study are to evaluate the current LRFD Specifications to assess the calibration of the code with respect to typical Texas U54 bridge girders, to perform a critical review of the major changes when transitioning to LRFD design, and to recommend guidelines to assist TxDOT in implementing the LRFD Specifications. This study focused only on the service and ultimate limit states and additional limit states were not evaluated. The available literature was reviewed to document the background research relevant to the development of the LRFD Specifications, such that it can aid in meeting the research objectives. Two detailed design examples, for Texas U54 beams using the LRFD and Standard Specifications, were developed as a reference for TxDOT bridge design engineers. A parametric study was conducted for Texas U54 beams to perform an in-depth analysis of the differences between designs using both specifications. Major parameters considered in the parametric study included span length, girder spacing, strand diameter and skew angle. Based on the parametric study supplemented by the literature review, several conclusions were drawn and recommendations were made. The most crucial design issues were significantly restrictive debonding percentages and the limitations of approximate method of load distribution.The current LRFD provisions of debonding percentage of 25 percent per section and 40 percent per row will pose serious restrictions on the design of Texas U54 bridges. This will limit the span capability for the designs incorporating normal strength concretes. Based on previous research and successful past practice by TxDOT, it was recommended that up to 75% of the strands may be debonded, if certain conditions are met. The provisions given in the LRFD Specifications for the approximate load distribution are subject to certain limitations of span length, edge distance parameter (de) and number of beams. If these limitations are violated, the actual load distribution should be determined by refined analysis methods. During the parametric study, several of these limitations were found to be restrictive for typical Texas U54 beam bridges. Two cases with span lengths of 140 ft. and 150 ft., and a 60 degree skew were investigated by grillage analysis method.

Description

Citation